The Research and Development Center for Radiation Technology (VINAGAMMA) was established under the Decision No.159/QD-BKHCNMT issued on February 14th, 2000 by the Minister of Science, Technology and Environment and managed by the Government Decree No.115/2005/ND-CP (Organization Chart). It is located in Linh Xuan Ward, Thu Duc District, Ho Chi Minh City, about 20 km from the city center (Direction to VINAGAMMA).
Irradiation services

VINAGAMMA-1 Irradiator  was designed and constructed by experienced experts in the fields of operation of industrial scale gamma Co-60 Irradiator  in Vietnam.

VNAGAMMA-1 was desinged and constructed for:

 Sterilization of  medical products: Petri disks, bottles, laboratory apparatus,  surgical gloves, syringes, infusion lines, cottons, dressing, cosmetic products, etc.

Pasteurization of foodstuff:

  Dried seafood  and frozen seafoods,  dried spicse, powder spices, agricultural products and all irradiated fruits for quarantine purposes

Research, development and application in the fields of radiation technology

SPECIFICATIONS

The type of the source: Co-60, or The source: Co-60

C-188/GIK-A6/R2890

Number of source racks and number of  modules in a source racks

3 and 4

Dimention of  tote boxe

50x67x90

Maximum processing speed (minimum irradiation time 80 min)

39 tote boxes/hour

Irradiated productivity according to density

Efficiency of radiation utilization, %

Density: 0.15g/cm3            

20.4± 0.3

Density: 0.45g/cm3

37.5±0.3               

(Dose Uniformity Ratio) –DUR

Value

Density: 0.15g/cm3            

1.40± 0.3

Density: 0.45g/cm3

1.67±0.3

Productivity of irradition (for 500 kCi, d=0.45g/cm3, dose = 3.5 kGy) 2,815 kg/h

1

Name of registration *
Address *
Phone *
Email *
Contact *
Mobile phone * *

2

Customers registered for treatment *

Name goods

Weigh (Gross)

Species

Size barrel (length x width x height) (cm)

Number of bins

Dose requirements (kGy)

Add

3

Date and time are expected to *

4

Note *
  • Note: If there is a change or a change in the history ly.Quy please at least one day prior notice to our sorting facilities.
  • Contact phone : 08.38975922
Cobalt-60 Irradiator

Cobalt-60 Irradiator

GAMMA COBALT-60/B IRRADIATOR

The gamma irradiator at VINAGAMMA is a multipurpose industrial scale type SVST-Co60/B. It was designed and fabricated by Institute of Isotopes Co. Ltd. (Hungary) and has been put into operation since March 15th, 1999 for two main purposes of sterilization of medical products and pasteurization of foodstuff.

SPECIFICATIONS

The type of the source: Co-60, or The source: Co-60

CoS-43HH

Number of source racks and number of  modules in a source racks

3 and 4

Dimention of  tote boxe

50x50x90

Maximum processing speed (minimum irradiation time 190 min)

20-24 tote boxes/hour

Irradiated productivity according to density

Efficiency of radiation utilization

Density: 0.2g/cm3            

17 %

 

 

(Dose Uniformity Ratio) –DUR

Value

Density: 0.2g/cm3            

1.3± 0.13

 

 
Productivity of irradition (for 500 kCi, d=0.2g/cm3, dose = 3.5 kGy) 2,054 kg/h